ECO NUMBER: VMS721_DEBUG-V0100 PRODUCT: OpenVMS Alpha OPERATING SYSTEM V7.2-1 UPDATE PRODUCT: OpenVMS Alpha OPERATING SYSTEM V7.2-1 COVER LETTER 1 KIT NAME: VMS721_DEBUG-V0100. 2 KITS SUPERSEDED BY THIS KIT: None. 3 KIT DEPENDENCIES: 3.1 The following remedial kit(s) must be installed BEFORE installation of this, or any required kit: o VMS721_UPDATE-V0100. o VMS721_PCSI-V0100. 3.2 In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None. 4 KIT DESCRIPTION: 4.1 Version(s) of OpenVMS to which this kit may be applied: OpenVMS Alpha V7.2-1. 4.2 Files patched or replaced: o [SYSLIB]DEBUGSHR.EXE (new image) 5 PROBLEMS ADDRESSED IN VMS721_DEBUG-V0100 KIT o The DEBUG command SHOW SYMBOL X in Y can fail. See the example below of a C file with a module name 'DEBUG_SUB': typedef float F32; F32 gsum; F32 gbat; void debug_sub (void); void debug_sub() -- COVER LETTER -- Page 2 8 February 2001 { gbat = gsum + gbat; return; } Here, the DEBUG command "SHOW SYMB g* in DEBUG_SUB will fail. Depending upon how the code is compiled, i.e., compiler version and/or compilation switches, the global symbol table entry for the routine 'debug_sub' can be upper- or lower-case. If it is lower-case, this command works fine. If the global symbol table entry for the routine 'debug_sub' is upper-case, then DBG$STA_GETSYMBOL (via LOOKUP_GBL called from DBG$STA_LOOKUP_GBL) matches the global symbol table entry and then finds and returns the corresponding non-global description of 'debug_sub' in the DSTs. Images Affected: - [SYSLIB]DEBUGSHR.EXE 6 KIT INSTALLATION RATING: The following kit installation rating, based upon current CLD information, is provided to serve as a guide to which customers should apply this remedial kit. (Reference attached Disclaimer of Warranty and Limitation of Liability Statement) INSTALLATION RATING: INSTALL_3 : To be installed by customers experiencing the problems corrected. 7 INSTALLATION INSTRUCTIONS: Install this kit with the POLYCENTER Software installation utility by logging into the SYSTEM account, and typing the following at the DCL prompt: PRODUCT INSTALL VMS721_DEBUG /SOURCE=[location of Kit] The kit location may be a tape drive, CD, or a disk directory that contains the kit. Additional help on installing PCSI kits can be found by typing HELP PRODUCT INSTALL at the system prompt -- COVER LETTER -- Page 3 8 February 2001 This kit requires a system reboot. Compaq strongly recommends that a reboot is performed immediately after kit installation to avoid system instability If you have other nodes in your OpenVMS cluster, they must also be rebooted in order to make use of the new image(s). If it is not possible or convenient to reboot the entire cluster at this time, a rolling re-boot may be performed. Copyright (c) Compaq Computer Corporation, 2001 All Rights Reserved. Unpublished rights reserved under the copyright laws of the United States. The software contained on this media is proprietary to and embodies the confidential technology of Compaq Computer Corporation. Possession, use, or dissemination of the software and media is authorized only pursuant to a valid written license from Compaq Computer Corporation. DISCLAIMER OF WARRANTY AND LIMITATION OF LIABILITY THIS PATCH IS PROVIDED AS IS, WITHOUT WARRANTY OF ANY KIND. ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY EXCLUDED TO THE EXTENT PERMITTED BY APPLICABLE LAW. IN NO EVENT WILL COMPAQ BE LIABLE FOR ANY LOST REVENUE OR PROFIT, OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL OR PUNITIVE DAMAGES, HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF LIABILITY, WITH RESPECT TO ANY PATCH MADE AVAILABLE HERE OR TO THE USE OF SUCH PATCH.