PROBLEM: (QAR 45825)		(Patch ID: OSF405DX-400001)
********
This patch fixes a problem that causes the X server's colormap entries to be 
corrupted. The current session's colors may become mixed up.  For example, the 
black may be white, the white may be red, and so on.

PROBLEM: (QAR 44365 and 46643)	(Patch ID: OSF405DX-400001)
********
This patch fixes a problem in which certain file system percent full values 
may be displayed incorrectly. The percent full values may not match (by more 
than 1%) the values displayed by the df command. This is especially true for 
relatively large file systems and for AdvFS file systems.

PROBLEM: (QAR 41445)		(Patch ID: OSF405DX-400001)
********
This patch fixes a problem with the dxsysinfo application. For systems that 
have the System V environment subset installed, dxsysinfo displays the 
/dev/prf device in its Device Information Area as a tape device and each time 
Update Devices is selected, another /dev/prf icon is added.

PROBLEM: (QAR 44882)		(Patch ID: OSF405DX-400001)
********
This patch fixes a problem with the dxsysinfo application. When a user logs 
out of the CDE session, the child process becomes orphaned and continues to 
run.

PROBLEM: (QAR 40964)		(Patch ID: OSF405DX-400001)
********
This patch fixes a problem in which the hard disk icons fail to display in 
the Device Information Area when the colormap is full or when a black/white 
screen is used.