PROBLEM:  (QAR 46878)	 	(Patch ID: OSF400-029)
********
This data corruption problem is difficult to detect as no error report, etc.
is given when it occurs. The data corruption can be identified by the pattern 
in the corrupted data. Commonly, at the point of corruption, there will be 3 
bytes of unknown data inserted into the valid data stream.

This problem is induced by a chip register behavior change between the 810 and 
810a. The register (DNAD) is used to calculate the next dma address whenever a 
dma transfer is interrupted by a phase change by the scsi device.

This problem can be reproduced using the UEG engineering test script 
"dt_tag_rotate_sh" which tests unaligned data accesses.


FILE(s):

/sys/BINARY/cam_psiop.mod 			subset OSFHWBIN400
CHECKSUM: 36007    216
/usr/sys/include/io/cam/siop/pci_scripthost.h 	subset OSFBINCOM400
CHECKSUM: 41447     16     RCSfile: pci_scripthost.h      RCS: 1.1.38.2